There should be no continuity. Humming Motor: If the pump motor makes a humming sound when starting up, you likely have a clogged impeller. cd77petanque.com Informacin detallada del sitio web y la empresa You can assist by removing the back cover and placing a fan behind the motor and try again after a day. I turn it off at the breaker & then turn it back on again, it displays rESET. Dear Davy, my pump was working two days ago then I switched it off. the motor makes humming sound but nothing happened, then the motor became burning hot. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? Automatic reset is immediate after error is corrected. I did find the black power wire lose on the pump when checking the wire connections, so I reconnected it but to no avail. Help. Hi again, I dont have a shaft seal replacement video, but there are many on youtube. It trips 20amp breaker after running 5 or 10 second. Setting it up this year and the pool filter lid keeps leaking. When the valve is positioned on the filter, it should slide over the standpipe tube, or the center pipe that is connected to the laterals will slide up into the bottom of the valve, and the valve is pushed down to make a tight fit against the filter flange, and then the clamp is supposed to hold it tightly. check that everything is tight and aligned. Hi Jim, sounds like an air leak, or low water in the pool, or a stuck skimmer weir blocking water flow into the skimmer. Hoses popping off could also indicate a high pressure problem after the filter, such as obstructed return lines, such as plugged or blocked wall returns, or closed valves. If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. After installing the new pump, priming it, it started running as normal, after a short time the new pump shut down and was very hot. This time around I purchased the t-3 cell model since my pool is below 15k gallons. I flipped on the breaker and the pump made this god awfully loud noise, immediately flipped it off. The breaker on the panel tripped. Theory and practice | Find, read and cite all the research you need on ResearchGate Fitness View More. The pump was about 13 years old. It seems to be coming from the wet side of the pump the strainer housing. First, in regard to my Hayward pump basket lid, it is hard to turn counter clockwise, when i need to remove it but it does turn. Hayward pumps use different shaft seals, you can find the correct one here: https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG . Replace the seal in the same orientation as you removed it, and reassemble. The mechanical shaft seal sits behind the impeller, and prevent water from leaking out along the motor shaft. I only rotated the one piece how can the screws not go right back in? Look on the cap for the MFD number and replace with exact duplicate. Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. All Products, View When running through all these checks and balances if it is noticed that there is not bond wire or that the tightening screws are not all secure, correct the issue. I open the plastic door, fill with water and sometimes need to do this several times in order for it to keep going. . Its likely good advice you are getting. I dont know if Im convinced the new pump is bad or not, or if I need higher voltage to the pump. With a test meter, you check power at the motor, and it should be within 10% of 120V or 240V, whichever the motor is wired for, and if not, the power is traced back to a point where it full power is found, on the meter. Remove all of the bolts around the top and pull out the Filter Nest, or all of the fingers. Is it rigid PVC or flexible pipe? Do you feel my capacitor is going bad or my motor? Hi i have a Hayward super pump when I turn it on it doesnt suck any water from the pool the filter pressure gauge is at 0 when I turn it off it makes a spinning noice. Hi Joe, Low Flow would be indicating that the water flow coming into the pump, heater or salt system is insufficient. Hi Mark, if the part is screwed onto the end of the shaft, that is called a centrifugal switch. IE9 and older versions are not supported. Weve had our Hayward for four years now never had any problems.tonight my husband vacuumed the pool then back washed it. Hi Josh, that sounds like the Display board, a circuit board that controls the display. You can check the visual motor check (if you have an intermatic clock), to see if the motor gears are turning, which means the timeclock motor is good and the power from the breaker is good. Hi lindsay, pump motors are normally too hot to touch, they run about 140 to the touch. Tough one, good luck! Hi Joe, make sure that the pump shaft is spinning freely. 5. low water level or skimmer weir blocking water flow Without seeing the union and setup, it is hard to say what is causing it but check for warping of the nut. If a LED is flashing, wait 60 seconds after starting the filter pump. Lube should not be the issue with the leak, not required. Even if it looks good, it could be bad. What should i do now? Hi the strainer housing must need to be tightened up. Pump making loud grinding noise, any solutions. Hi David, impellers that have signs of wear are usually operating without a problem. Anyone have this issue or have any recommendations? Or a stuck skimmer weir. I would start by lubing the pump lid o-ring with pool lube, and trying to tighten the lid a bit more if you can. If it is not, re-align your flow switch. 2017). Yes, very important to fill the pump up with water before running, or prime the pump from a bucket or garden hose. Could be a change in vibration, press down on the pump, to see if the tone changes. Please note: The majority of our literature and brochures are in English only. Hello, I have a H200 natural gas heater . Hi, I have a Hayword pump and when I turn the pump on I have water coming out the bottom of the pump in the back, and trips the GFI OUTLET, could this be a bad seal? So, that leads me to the hose having splits, and drawing air in from a few small slits or holes in the hose, or else the hose is crimping due to the strong suction of the pump.
When I turned the pump on it is very loud and the pump is not moving water. https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual the first pdf link is the older model H150, the second .pdf link is the newer H150 models, altho it may not make a difference. Hi Renaud, many motors come wired to accept 230V, but are reversible to 115V. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 We would like to show you a description here but the site wont allow us. We have parts for the Super pump. After that, putting it to filter (following the backwash) ramps the flow to full strength until the gradual decline cycle starts again. Currently it is at pool level. Hayward should be able to help, http://www.haywardnet.com see for contact info. Automatic reset is immediate when the switch opens. 4. remove rear motor cover, loosen screw that holds capacitor (9 oclock) and move it out of the way, so you can fit a 7/16 wrench on the rear of the motor shaft, behind the centrifugal switch. Make sure that the fitting that goes into the pump has no air leaks, which is the most common air leak area. When the pump comes on a massive amount of bubbles comes out of the return line in the bottom of the pool. No leaks, pressure is good, suction is good, connections seem right. On initial trial for ignition. Any ideas or what else to check? Long story short, bought a house that had an above ground pool that would not get the pool clear. To Become a Customer please Click Here > Skip to the end of the images gallery Skip to the beginning of the images gallery HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 Sku: BLUE ESSENCE-35 Be the first to review this product Hi there, I have a 2-speed (hi and low) Hayward pump. I have a six year old Hayward sp3400vsp and theyre recommending I replace it with the pen take intelliflo. Its concerning to suddenly hear strange sounds coming from your Hayward pool pump. I can turn the temperature up but not down. 4. leaky valve or unions in front of pump Reinstall and add new DE powder. Hi Freddy, usually a clicking noise may be a relay, which are used in control systems for pools. Fourth, check the motor shaft to be sure that it spins easily by hand, fifth, you can check the capacitor (for capacitance), if the motor still isnt starting. Pump is 29 years old so wouldnt surprise me if impeller is failing. I have a Hayward Power-Flo Matrix and seems to be working fine when it is running the pool. I have a Hayward Power-Flo LX pump that went out and I bought the identical one thinking it would be an easy replacement. We have a c48l2n134b3 pump. When I try to turn on high speed it sounds like its jamming and then the breaker trips. it continues to cycle this way. Today it completely shutdown at some point and tripped the breaker in the house. Flex pipe used on skimmers can eventually narrow and crimp, leaving a small opening that clogs easily. For some time now I have been pushing along with my old cell (t-9 model). What is the problem with those other motors? Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. The most common places for an air leak on a pump include around the pump lid (must be really tight, with lubed o-ring), or a loose incoming water pipe bringing water (and air) into the pump. Interesting enough, if I place it in super chlorinate mode, it will produce chorine. Also check that water level is good in pool, and skimmer weir is not blocking water flow. Clean the filter cartridge well, allow it to dry fully, and then replace it back in the filter tank. Plunger was a good idea, a Drain King can also be used, from the pump, to blow debris back to the skimmer. Hi Gail, overheating can be caused by the wrong wire size from breaker to motor, or loose wire connections, or over-voltage coming into motor, or lack of ventilation around the motor (mulch piled up, or big bushes close by, or placed in a box cover), but its can also be a fatal fault inside the motor. The water level is good. If it blows again then I guess youll have to replace the pump body, which is usually about $100-200 cheaper than the cost of the whole pump. The problem lies, where the power dies as they say. So you could cut off the pipe and cap it yes, although it might be worth investigating the repair cost the crack could be just 2 foot below the ground, near the pump/filter. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell - http://bit.ly/2TPpK5IStabilizer - http://bit.ly/3aCeEa7SUBSCRIBE for FREE swimming pool care and maintenance videos every week: http://bit.ly/SubscribeINYO ****VISIT our blog for weekly swimming pool tips, tricks, and more! Bob. Hose it off well, and inspect the tubes for any holes, and if found, replace them with new. If i knew what make/model of pump you have, I could be more specific. First time pool owner (obviously dont know what we are doing). Maybe thats off. The Pool is a Roman 23 in ground. "headline": "Hayward Pool Pump Troubleshooting",
The salt cylinder is clean. Pool360 - Blue-essence-20 20k Gal Salt Chlorination System - Poolcorp Sir, I have a Hayward Ecostar 3400 variable speed pump and will not run anymore. After 30 seconds it overheats and shuts down. Filter. Should it be very hot to touch or is this an indicator for a capacitor problem? But most plastic impellers are closed nowadays, with non-visible vanes. Problem is now the pool will not clean up (algae) and the pump is slow to prime. For slide valves (aka push-pull valves), an o-ring on the bottom plunger disk has gone missing or is worn, torn or badly deteriorated. All If the capacitor is bulged or cracked, or looks like it is burned or charred, you can assume that it is D.O.A. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. I Manually turned the shaft (which was not turning freely), while the motor was humming. If the set screws loosen, the impeller can slide forward and contact the pump housing, and grind both the bronze housing and bronze impeller down rapidly. Get support by contacting us online, hayward The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. 5. inspect all wires inside the back of motor, looking for one that is disconnected, cut, crimped, or two metal terminals touching each other. The Tristar VS would be a good choice and easy to plumb, since its the same pump. All the hoses have new Teflon tape and they are secured. heard a click at the plug. v when it is turned to 230v and re wired for 220-230 v it makes no noise at all. If they wont or cant fix it, call a electric motor repair shop to visit, or pull the pump and take it to them for service, or attempt the (easy) repair yourself. Don, melted shrouds can indicate that the something may be laying on the burner tray, causing flames to shoot out a little sideways, or something is laying on (or clogging) the heat exchanger, allowing hot gas to build up inside the heater, slowing down the exhaust rate. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Could have been an outlet problem too, make sure wires or terminals arent touching anything except each other. Learn more about pool care and repair. Do you have any tips? We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. Ive read online it is most liked a valve that is faulty in some way. We have a sand filter and no pressure gage. Hello , This is an inactive thread. Thanks. Have you checked the cells voltage, amperage, or done anything other troubleshooting? Hi Doug, good question that indicates that there is an air leak coming into the pump. Third possibility is just that the pump capacitor is bad, if the motor wont turn over, wont spin. The correct lateral assy for the S210 filter would be the SX210DA if you used a smaller assy, the pipe wont reach all the way into (inside of) the multiport valve base, and allow sand to enter the pipe but just a theory, you likely used the correct and full height SX210DA? American Freight San Antonio, Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. Is there a reset button or do I just need to wait until the water evaporates and it should turn back on? Did you figure out your problem? Sun was beating on it. Well the electrician said it was a bad motor and to contact hayward to replace. The plastic shroud or cover over the impeller? If it is a 15amp breaker, but the pump wants 9amps and the aquatrol wants 7 amps, (for example, made-up numbers) thats a total of 16amps, too much. What do you think? Could be too much or too little sand, the filter should be about 2/3 full of sand. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. NO one can get the cover off the darn thing. Zero on the gauge indicates no water flow, so if not an air leak it could be a clogged line, pump basket or impeller. Joe, must be a bad motor yeah, to pull 58 amps, never heard of such a thing! Copyright 2022 In The Swim. crooked house (2008 trailer) Can I replace this pump housing or do I need a new pump? Could be loose fitting on hoses. No reset on the pump motor, but a little water on the wiring, and it will pop a GFI outlet. If you have a visible motor shaft, just behind the impeller, common on older pumps or booster pumps, you can just grab it with straight pliers and turn it back and forth. I have it set for a T9 cell. 2. If the motor is fried, you can either replace the motor and shaft seal or spend more, and replace the entire pump (although the motor is the only thing you would really need). My Hayward mother is a 1.5 hp. Thanks in advance for any help you can provide, the pool should be done in the next few days and need to figure out this pump situation. Though it is a different control, they use the same cell; so if you are getting a temperature reading of 215, you need to replace the cell. Could vibration over time wear the pump housing? I presume Ill be looking at buying a new pump next year. Loose pump lid, filter lid, air bleeder, probably around the filter, allowing the filter to drain down, and fill with air. You must log in or register to reply here. Hi Michelle, If the pump and motor are too large and powerful for your filter size, it would create this situation. Pool Supplies Near Me Open Now, Amp draw is 15 amps. The pump works and will pump out whatever water is in the line, but wont prime and suck the water from the pool. Likewise, it could be any other obstruction after the pump (partially clogged pipes, small pipe size, partially closed return valves) all of which will produce higher than normal filter pressure. I have mud in my filter so I guess I have a underground broken pipe. Check the shaft for free spinning movement, and check the capacitor for signs of failure (bulges, cracks, smoke). You will get much more visibility by. If your hose has union connections that are tightened to connect to the filter, you may try some Teflon tape on the valve threads, or may need a new hose assembly, if the union threads are damaged. This noise does not happen when the water is flowing through the heater but it is not turned on. The sound you reference pumping rocks sounds like a pump that is cavitating, or starved for water. It had been running ok this summer. A common mistake is to install the spring seal half backwards. If you get no response from your Hayward pool pump when you flip the switch, first verify the terminal board connections match the wiring diagram on the motor data plate label. Also check other wires in the back of the motor. Fox example, a 1 hp Whisperflo creates twice as much flow as a 1 hp Superpump. Most likely, and unfortunately yes. What are the amp and volt readings for the new cell? Any ideas why this would happen? replace the entire pump with exact replacement. Im having a problem with my super pump. Is it possible that the filter is the problem? 99% of the time its no problem 1% of the time something could burst, usually a plumbing fitting, a bad glue joint or clamped fitting. 3. 1. "@type": "Person",
Now if your pressure is jumping up to 20 psi very rapidly (hours or days), the filter media (sand, de or cartridge) may need to be replaced. If your sweeper has a booster pump, could be a problem with a clogged impeller, or air leak into the pump, or some other pump issue. Since you didnt say it trips a breaker, its probably not a short or ground-out of power, although it still could be, typically a wire touching metal other than the terminals on both end of the wire. My pump keeps overheating and shutting off. That is usually what causes the rattle. Any suggestions?? Hi, that could be many things, from low water level to a broken impeller, but its usually an air leak. No loose wires or insect infestation. I closed the pool for winter. When he went to turn the pool back on it made a slight humming noise like it was trying to come back on but it wouldnt turn on. Just replaced my old Polaris booster pump, 3/4 hp, with a 1hp pump. Then check power (volts) coming into motor to verify and if it still wont come on (and makes no attempt to) its likely dead. Good luck ~, Hi, I just replaced my 3/4 Hayward pump with a 1hp. Do I need to prime it? You can buy replacement drives I believe, that may be the (expensive) cure for the problem. I have called a repair company since the pump is under warranty and they told me that it is almost NEVER the pump and therefore if it is something else I will have to pay $89/hour for their serviceso I was hoping to exhaust all other possibilities before coughing up the moneyCan you recommend any tests that I can do? So we have power to the pump. The higher the pump is elevated above the water level, the more struggles this can cause. Thanks again! Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. Outlet works fine. Dont feel that resistance when bumping. 2 yrs is unusual for bearings to go. Thanks Davy for your quick reply. Reinstalled Same problem recycled power. If the motor was submerged, it may not recover. Incorrect sizing can cause multiple problems, including low water flow. Check if the pump will now run. It is being practiced by thousands of pool owners just like you. Superpump lid gaskets are a square cut gasket that can come out of the groove easily, be sure it is seated properly, and lube it with Teflon pool lube regularly. Hello there, if he customer wants to install a VS pump (required in 2021 for all new pumps), they could do that now. Wait for the relay to click (5 to 10 seconds). my two speed Hayword pump clicks when Drive Error is a major fault. See if your test button has popped out on the outlet, or perhaps you have one on the breaker, a test/reset button. That is the black cylinder in the rear of the motor, located at 9 oclock. Might be some voltage issues? Could possibly be loose wires on the motor or timer, possibly a loose centrifugal switch or stationary switch on the motor, or maybe the windings in the motor are shorting out. Good thing is our power company is offer rebates for new energy efficient pumps. Now if you do find power at the motor, and the wires are screwed tightly, but no sound, no movement, and the breaker doesnt trip it could be a bad motor. Spray some ant killer around, and replace the capacitor, but first, check all connections, maybe check incoming power (to the motor) if you have a test meter. Check it out, it could start a fire! The cord does feel warm to the touch. Make sure the stationary switch, triangular shaped, screwed in at 6 oclock, is tight and intact. I have a Haywood swim pro voyager and it is making a loud vibration noise. Hi Davy, Turn it off fully, then back on again. It can also be a loose pump lid allowing air to creep in around the o-ring. If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. ), it could be a bad breaker, they can fail or become too sensitive with age. Diagnosing and Troubleshooting Your Hayward Aqua Rite System - INYOPools "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
If thats not it pull the motor out of the pump, and test the motor briefly to see if the sound continues, if so I would expect bad bearings, or perhaps a loose shim washer, inside the motor, under the front or rear end bell. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. Loose wiring, or broken wires, or wires nearly touching each other, and arcing. Give the cell an acid soak and it should clear the blockage. They disparate as they move through the pool. The Inspect Cell LED (only) flashes or stays on when: The Check Salt & Inspect Cell LEDs flash together when: The Check Salt & Inspect Cell LEDs will stay ON when: Step 1: Check your system to confirm that you have programmed the correct cell size. If so, shut off power and see if the motor shaft will spin. https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS the sound may possibly be a problem with the internal bypass, located in the front header. Hi Don, if you have four suction lines coming into the pump, that would be skimmer, skimmer, main drain and spa drain? You find these in our valve parts department or use one of our multiport valve rebuild kits. I wonder if the lines are clogged or a pipe is partially collapsed. I would suggest replacing the pump with the same exact pump, which is matched to your filter size presumably. If you see any damage, replace your flow switch. Also the pool breakers are loose now. Likely not a problem with the pump itself. Hi Leah, when the pump is barely pumping, the problem is either in front of the pump or after the pump. What am I doing wrong?? Too bad Hayward doesnt make this more clear on their installation instructions and labeling. Issues with Hayward Blue Essence | Trouble Free Pool Have an old Hayward super II pump, worked fine last fall, this spring at startup very low volume. IE9 and older versions are not supported. I had an old hayward 1.5 hp power flo matrix 2 speed pump. If still nothing, look for damage in the rear of the motor, something burned, melted, loose, or pinched or cut wires. Open faced impellers need very large pliers, or a strap wrench, some have special tools to remove open brass impellers. Is this the proper way to wire this salt water panel or does it also have to have a cable going into N0-2? Repair or replace any tripped breakers or blown fuses. Hi William, the on/off switch is sold as an entire end-cap piece, including the rear cover, the yellow wire would not be a part that is sold, I suppose you could make it yourself ? Hi Jodi, that could be two things either the pump impeller is severely clogged, keeping the motor shaft from turning or if the shaft spins freely, it is likely the capacitor (black cylinder in rear of motor) that has failed. Hi Rachel, when there is no sound at all i would check the circuit breaker to be sure it is on. Is this normal? Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. everything worked fine until we installed this pump. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the ' '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Hi Steven, probably the breaker tripped or the GFCI test button popped out due to some water touching some wire. Just replaced the upper lid on my Vari-flow and spider gasket, also changed out 300 lbs filter sand. Its linked to an AutoChlor switcher and comes on twice a day but failed to switch on a couple of days ago. If you do have power at the motor terminal board, look for loose wires, crimped wires, broken wires Suspect the capacitor (black cylinder located at 9 oclock), these can be tested, or if looks burnt, bulged, crack or leaking, replace with the exact same MFD number capacitor. Fix this problem simply by tightening or adjusting the wires and connections in the motor. Terrible storms 2 nights ago. Maintenance. You could also check incoming voltage, and wire connections, as fluctuating current can cause an overheated motor, but if its very old, it may just be on its way out, sorry to say at which point you could replace just the motor and shaft seal, or the entire pump. IF so, replace the fitting, or pack pool putty or silicone around the fitting, and leave it running for 24 hours, until the sealant sets up hard.